Optimizer

Design software Energy Optimizer

Nullstill
Tilluft
Fraluft
m³/h
m³/h
Pa
Pa

Vinter

°C
%RH
°C
%RH

Oppvarming

°C

Sommer

°C
%RH
°C
%RH

Kjøling

°C

Pegasos Z HP-E eAir

Tilluft
Fraluft
70 %
70 %
844 m³/h
844 m³/h
100 Pa
100 Pa
146 W
140 W
1.22 kW/(m³/s)
1247 m³/h
1277 m³/h
218 Pa
229 Pa
48 %
51 %

Lyder

Lw
LwA
63.3 dB
55.9 dB(A)
51.9 dB(A)
48.9 dB(A)
81.1 dB
73.4 dB(A)
72.5 dB
59.8 dB(A)
72.5 dB
59.9 dB(A)
85.6 dB
79.6 dB(A)

Informasjon om enheten

Ø 250 mm
1250 mm
1400 mm
677 mm
203 kg
Tilluft: F7, ePM1 60 %, pose
Fraluft: M5, Coarse 80 %, pose
Høyre
P06 214 0003
400 V/50 Hz, 3~, 3C16A
Elektrisk kanalvarmer E: 230 V/50 Hz, 1~, 1B16A
Aggregat: 2 x DN32
6743 W

DWG

Vinter

Varmeveksler

Standard + HP
-20 °C / 90 %RH
90.6 %
18.0 °C / 25 %RH
26.3 kJ/kg / 3.2 g/kg
26.3 °C / 15 %RH
34.7 kJ/kg / 3.2 g/kg
14.67 kW
1.12 kW
0.67 kW

Elektrisk kanalvarmer E

3000 W kanal Ø250
18.0 °C / 25 %RH
230 V/50 Hz, 1~, 1B16A

Årlig

Oslo,
Norge
90.6 %
33 472 kWh
0 kWh

Ecodesign

690 W/(m³/s)
1600 W/(m³/s)
1320 W/(m³/s)

Sommer

Varmeveksler

Standard + HP
26 °C / 50 %RH
0.0 %
15.0 °C / 99 %RH
41.5 kJ/kg / 10.5 g/kg
13.0 °C / 100 %RH
36.6 kJ/kg / 9.3 g/kg
3.78 kW / 4.70 kW
2.26 kW
1.45 kW

Elektrisk kanalvarmer E

3000 W kanal Ø250
15.0 °C / 99 %RH
230 V/50 Hz, 1~, 1B16A